Ten 890×890×70 mm concrete panels were tested under in-plane pure-shear monotonic loading conditions to evaluate the effectiveness of steel fibers in controlling concrete cracking. The results of the tests indicate that concrete elements exhibiting ductile behavior, good shear resistance, and…
Ten 890×890×70 mm concrete panels were tested under in-plane pure-shear monotonic loading conditions to evaluate the effectiveness of steel fibers in controlling concrete cracking. The results of the tests indicate that concrete elements exhibiting ductile behavior, good shear resistance, and good crack control characteristics can be obtained with an adequate addition of steel fibers. Assessments were also made of the influence of fiber aspect ratio, fiber length, fiber tensile strength, fiber volume content, and concrete compres- sive strength on the crack control performance of fiber reinforced concrete (FRC). In addition, finite element (FE) analyses were performed to investigate whether currently available constitutive models can be utilized to accurately represent the behavior of the FRC panels tested. The analytical results indicate that improved con- stitutive models for tension response and crack spacing of FRC are required for successful finite element modeling.