FraMCoS 7 2010 Jeju, South Korea

Evaluation of ungrouted tendon ducts in prestressed concrete structure by SIBIE

Stack Imaging of spectral amplitudes Based on Impact Echo (SIBIE) procedure is developed as an imaging technique applied to the impact-echo, where defects in concrete are identified visually at the cross-section. In this study, the SIBIE procedure is applied to…

First page of: Evaluation of ungrouted tendon ducts in prestressed concrete structure by SIBIE
Year 2010
File Size 1.2 MB
Download PDF (1.2 MB)

Abstract

Stack Imaging of spectral amplitudes Based on Impact Echo (SIBIE) procedure is developed as an imaging technique applied to the impact-echo, where defects in concrete are identified visually at the cross-section. In this study, the SIBIE procedure is applied to identify ungrouted post-tensioning ducts in prestressed concrete. Concrete slabs containing an ungrouted duct, a partially-grouted duct, and a fully- grouted duct of metal and polyethylene sheaths were tested. It is concluded that results are successful.