FraMCoS 7 2010 Jeju, South Korea

Fiber reinforced concrete characterization through round panel test Part II: analytical and numerical study

The round determinate panel according to ASTM was found to be a reliable, consistent and re- peatable test method for the measurement of the energy absorption in Fiber Reinforced Concrete (FRC) com- posites. A smaller panel was proposed and experimentally…

First page of: Fiber reinforced concrete characterization through round panel test Part II: analytical and numerical study
Year 2010
File Size 2 MB
Download PDF (2 MB)

Abstract

The round determinate panel according to ASTM was found to be a reliable, consistent and re- peatable test method for the measurement of the energy absorption in Fiber Reinforced Concrete (FRC) com- posites. A smaller panel was proposed and experimentally investigated by the authors in the Part I of the pre- sent paper. The results of several tests on about 100 round panels (ASTM and small panels) evidenced a lower scatter, as in the larger ASTM panels, with significant advantages. In fact, small round panels are easier to place and handle and their weight is only 40 kg, if compared to the 91 kg of the ASTM panel. Given this broad experimental database, an analytical approach is herein reported toward the definition of a suitable simplified cohesive stress-crack width constitutive law for FRC, determined from round panel tests according to the re- quirements of the main structural codes. To this aim, crack development was measured during the tests. In ad- dition, a kinematic approach was proposed to determine the constitutive laws from the load point displacement of the slab.