This paper deals with the study of fiber-matrix bond properties in ultra-high performance concrete (UHPC) by performing pullout tests on straight single steel fibers of varying aspect ratios, embedded partially in the concrete matrix. The interface between the fiber and…
This paper deals with the study of fiber-matrix bond properties in ultra-high performance concrete (UHPC) by performing pullout tests on straight single steel fibers of varying aspect ratios, embedded partially in the concrete matrix. The interface between the fiber and the matrix plays a major role in enhancing the toughness of the material. It is the weakest link in the composite from where damage initiates. Hence, it is crucial to study the interface bond properties, and the most direct method to study them is the single fiber pullout test. The pullout load vs. fiber slip is recorded to analyze the pullout behavior of the fiber. The failure mechanism of fiber embedded in matrix takes place in different stages. To identify these stages, acoustic emission (AE) technique is implemented. An AE parameter based on Shannon’s entropy is used. The AE entropy, being independent of threshold, in addition to AE event amplitude and energy are recorded. The study establishes a correlation between the AE signal parameters and different stages of damage in the fiber pullout process. It is observed that the AE entropy parameter differentiated the damage stages in the fiber pullout process more efficiently than the other AE parameters.