FraMCoS 5 2004 Vail, Colorado, USA

Testing and Modelling of Steel Fibre Reinforced Concrete Beams Designed for Moment Failure

As part of a Norwegian industrial research project, several experimental investigations of the effect of steel fibre reinforcement (SFR) in concrete beams have been carried out in the period 2000-2003. Four test series, consisting of respectively 4, 3, 9 and…

First page of: Testing and Modelling of Steel Fibre Reinforced Concrete Beams Designed for Moment Failure
Year 2004
File Size 242 KB
Download PDF (242 KB)

Abstract

As part of a Norwegian industrial research project, several experimental investigations of the effect of steel fibre reinforcement (SFR) in concrete beams have been carried out in the period 2000-2003. Four test series, consisting of respectively 4, 3, 9 and 36 beams designed for moment failure, have been carried out. The following parameters were investigated: Ordinary vs. self compacting concrete, fibre volume, fibre length, cross section height, and influence of ordinary reinforcement. In 10 of the beams, SFR was used in combination with a relatively small amount of ordinary reinforcement, which should ensure sufficiently ductile structural behaviour. While the two first series were parallel with ordinary or self compacting concrete, the third series consisted of beams with different cross section height (150, 250 and 500 mm). A significant size effect on the structural behaviour was expected, especially for beams without ordinary reinforcement. The fourth series consisted of smaller beams (150/150/600) sawn out from structural elements, ie walls and slabs in realistic sizes, produced on a construction site. A new standard test method, which also includes determination of residual strength and evaluation of the real fibre content, is proposed. The post-cracking tension-model used in the finite element analysis, is based on a bilinear σ-w relationship. Both the discrete cracking and the smeared cracking approach have been used. A theoretical expression for the tensile force resultant in the fibres crossing a crack is deduced, and afterwards used to determine an expression for the residual tensile strength. Special attention is paid to the fibre fraction, which is defined as the relative amount of fibres crossing a crack plane. Its theoretical value is related to results from fibre counting, which for some of the series showed results over a wide variation range.